TM 9-2320-364-20-4
2-3153
Remove all jewelry such as rings, dog tags,
bracelets, etc. If jewelry or tools contact
positive electrical circuits, a direct short may
result. Damage to equipment, injury or death
to personnel may occur.
CONNECTOR
MC185
(1) Disconnect CHU wire harness
connector MC185 from CHU control
box.
(2) Set multimeter select switch to ohms.
(3) Is there continuity between connector
MC185 terminal F and terminal G of
CHU wire harness?
(a) If there is continuity, replace CHU
wire harness (Para 21-20).
(b) If there is no continuity, wires 1495
and 1496 are not shorted.
(4) Connect CHU wire harness connector
MC185
CONTINUITY TEST
F
G
A
B
C
D
E
F
G
H
I
J
|