TM 9-2320-364-20-4
2-3218
2-47. GENERAL INSTALLATION INSTRUCTIONS (CONT).
f.
Hose and Fitting Tightening Procedure.
NOTE
Tighten hoses and fittings as
required in Apendix E or in each
maintenance task. If a torque
wrench and crowsfoot are not
available or cannot be used, use
following procedure.
(1)
Install hose nut (1) on fitting (2).
NOTE
When turning effort increases,
hose nut seat is in contact with
fitting seat.
(2)
Tighten hose nut (1) until seated on
fitting (2).
NOTE
Alignment marks allow the
mechanic to count the number of
flats the hose nut has rotated
during tightening.
(3)
Scribe alignment mark on hose nut (1)
and fitting (2).
(4)
Tighten hose nut (1) until mark on
hose nut has rotated correct number of
flats (Refer to Table 2-67).
Table 2-67. Recommended Flats Rotation
Dash
SAE 37 Degree
SAE 45 DEGREE
37 DEGREE
No.
Flared Hose and Fitting
Flared Hose and Fitting
Flared Tube
-4
1 1/2 - 1 3/4
1 -1 1/4
2 1/4 - 2 3/4
-5
1 - 1 1/2
1 - 1 1/4
2 1/4 - 2 3/4
-6
1 - 1 1/2
3/4 - 1
2 1/4 - 2 3/4
-8
1 1/4 - 1 3/4
1 -1 1/4
2 1/4 - 2 3/4
-10
1 1/4 - 1 3/4
1 - 1 1/4
2 - 2 1/2
-12
1 - 1 1/2
1 - 1 1/4
2 - 2 1/2
-16
3/4 - 1
-----
2 1/4 - 2 3/4
-20
1/2 -3/4
-----
1 1/4 - 1 3/4
-24
1/2 -3/4
-----
3/4 - 1 1/4
-32
3/4
-----
1 - 1 1/4
ALIGNMENT
MARKS
1
2
37
37
45
45
37
37
MALE HALF
FEMALE HALF
MALE HALF
FEMALE HALF
MALE HALF