TM 9-2320-364-20-4
3-14
3-5. RIGHT ROCKER COVER AND GASKET REPLACEMENT (CONT).
b.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all parts with drycleaning solvent.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only with
effective chip guarding and personal protective equipment (goggles/shield, gloves, etc.) or
injury to personnel may result.
(2)
Dry all parts with compressed air.
(3)
Blow out groove in rocker cover with compressed air.
(4)
Inspect all parts for holes, cracks, chips or stripped threads. Replace damaged parts.
c.
Installation.
(1)
Install seal (15) in rocker cover (7).
(2)
Install shell (14) in seal (15) with breather
tube stub toward rear of engine.
(3)
Install retainer (13) and element (12) in
shell (14).
(4)
Position retainer plate (11) over
element (12) and install three screws (10) in
rocker cover (7).
|