TM 9-2320-364-20-4
4-20
4-5. AIR FILTER REPLACEMENT (CONT).
Air filter fits tightly around air
cleaner housing. Even pressure
must be applied around perimeter
of air filter. This can be done by
either prying evenly around air
filter or by moving around air
filter while prying with light
pressure. Failure to comply may
result in damage to parts.
(2)
Remove air filter (3) from air cleaner
housing (2).
NOTE
Perform Step (3) only if gasket is
damaged.
(3)
Remove and discard gasket (4) from air
cleaner housing (2).
(4)
Wipe inside of air cleaner housing (2) with
damp cloth to remove contaminants.
b.
Installation.
NOTE
Perform Step (1) if gasket was
removed.
(1)
Install gasket (4) on air cleaner housing (2).
(2)
Install air filter (3) in air cleaner housing (2).
(3)
Install 12 nuts (1) on air cleaner housing (2).
Tighten nuts to 90 to 110 lb-in (10 to 12
N.m).
c.
Follow-On Maintenance:
Reset air cleaner restriction indicator, (TM 9-2320-364-10).
Remove wheel chocks, (TM 9-2320-364-10).
END OF TASK
|