TM 9-2320-364-20-4
2-2987
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive,
solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water.
(1) Set multimeter selector switch to
ohms.
(2) Is there continuity on wire 1435
between differential lockup solenoid
connector, terminal 2 and a
known good ground?
(a) If there is no continuity, repair wire
1435 (see schematic Fig 2-72) or
notify DS Maintenance, and
perform Steps (3) and (4) below.
(b) If there is continuity, replace
differential lockup
solenoid (Para 12-40).
(3) Connect solenoid connector to
differential lockup solenoid valve M51.
(4) Tighten connector screw and coat
head of connector screw with
adhesive.
CONTINUITY TEST
|