TM 9-2320-364-20-4
2-2996
2. DIFFERENTIAL SIDE TO SIDE LOCKUP WILL NOT ENGAGE WITH CTIS IN
EMERGENCY WITH TRANSFER CASE IN LOW (CONT).
11.
Is continuity measured
between HI RANGE LOCKOUT
relay R23, terminals 30
and 87?
Replace HI RANGE
LOCKOUT relay R23
(Para 7-95).
Verify repair, go to
Step 16 of this Fault.
YES
NO
Dash lights operate indicating
circuit breaker CB8 OK.
Horn operates indicating circuit
breaker CB16 OK.
Air lines and fittings OK.
Differential lockup solenoid
valve OK.
Wire 1435 OK.
Differential lockup solenoid OK.
Wire 1882 OK.
Wire 1888 OK.
Wire 1885 OK.
CTIS controller OK.
Wire 1435 OK.
HI RANGE LOCKOUT relay
R23 faulty.
Wire 1885 faulty.
Wire 1890 faulty.
DIFF LOCK relay R21 faulty.
Wire 1093 faulty.
Start switch S13 faulty.
Wire 1095 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R#89.
HI RANGE LOCKOUT relay R23
is faulty if 24 vdc is measured.
WARNING
12.
Is continuity measured on
wire 1885 between HI RANGE
LOCKOUT relay R23, terminal
87 and DIFF LOCK relay R21,
terminal 85?
Repair wire 1885 (see
schematic Fig 2-72)
or notify DS
Maintenance.
Verify repair, go to
Step 16 of this Fault.
YES
NO
Dash lights operate indicating
circuit breaker CB8 OK.
Horn operates indicating circuit
breaker CB16 OK.
Air lines and fittings OK.
Differential lockup solenoid
valve OK.
Wire 1435 OK.
Differential lockup solenoid OK.
Wire 1882 OK.
Wire 1888 OK.
Wire 1885 OK.
CTIS controller OK.
Wire 1435 OK.
HI RANGE LOCKOUT relay
R23 OK
Wire 1885 faulty.
Wire 1890 faulty.
DIFF LOCK relay R21 faulty.
Wire 1093 faulty.
Start switch S13 faulty.
Wire 1095 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICER #91.
If there is no continuity, DIFF
LOCK relay R21 will not
operate.
WARNING
Read WARNING
on Page 2-2997
Read WARNING
on Page 2-2997
|