TM 9-2320-364-20-4
7-179
b.
Disassembly.
Keep all moisture and oils off
lamp. Do not touch lamp with
bare hands. Use a clean dry cloth
to hold lamp while installing
lamp in blackout light.
(1)
Loosen four captive screws (7) and cover
from blackout light (2).
(2)
Remove and discard gasket (9) from
blackout light (2).
(3)
Remove lamp (10) from lamp socket (11).
c.
Cleaning and Inspection.
(1)
Inspect lamp socket for corrosion.
(2)
Inspect lens for cracks.
(3)
Inspect light housing for cracks.
d.
Assembly.
Corrosion inhibitor contains
alkali. Do not get in eyes; wear
goggles/safety glasses when
using. Avoid contact with skin. In
case of contact, immediately
wash area with soap and water. If
eyes are contacted, flush eyes
with large amounts of water for
at least 15 minutes and get
immediate medical attention.
(1)
Apply anti-corrosion silicone compound
to inside of lamp socket (11).
(2)
Install lamp (10) in lamp socket (11).
(3)
Position gasket (9) in blackout light (2).
(4)
Install cover (8) on blackout light (2) with
four captive screws (7).
|