TM 9-2320-364-20-4
2-3009
(1) Set multimeter selector switch to
ohms.
(2) Is there continuity on wire 1435
between interaxle solenoid connector,
terminal 2, and a known good ground?
(a) If there is no continuity, repair wire
1435 (see schematic Fig 2-72) or
notify DS Maintenance, and
perform Step (3) below.
(b) If there is continuity, wire 1435 is
OK.
(3) Connect interaxle solenoid connector
to interaxle solenoid valve M50.
(4) Tighten connector screw and coat
head of connector screw with
adhesive.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water.
|