TM 9-2320-364-20-4
7-247
NOTE
Connectors are removed by gently prying on tab and pulling apart connectors.
(2)
Disconnect connector (6) from DDEC oil temperature sensor (7).
(3)
Remove DDEC oil temperature sensor (7) from tee (8).
b.
Installation.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
(1)
Apply sealing compound to threads of DDEC oil pressure sensor (7).
(2)
Install DDEC oil temperature sensor (7) in tee (8).
(3)
Connect connector (6) in DDEC oil temperature sensor (7).
8
7
6
DOOR
SHOWN
REMOVED
FOR CLARITY
|