TM 9-2320-364-20-4
7-278
7-84. DIFFERENTIAL PRESSURE SWITCH REPLACEMENT (CONT).
(4)
Remove hose 2922 (4) from elbow (3).
(5)
Remove screw (5), locknut (6), differential
pressure switch bracket (7) and differential
pressure switch (8) from bracket (9).
Discard locknut.
NOTE
Note position of elbows prior to
removal.
(6)
Remove two elbows (3) from differential
pressure switch (8).
b.
Installation.
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
NOTE
Install cable ties as required.
Install elbows in position as
noted prior to removal.
(1)
Apply sealing compound to elbows (3).
(2)
Install two elbows (3) on differential
pressure switch (8).
(3)
Install differential pressure switch (8),
bracket (7), screw (5) and nut (6) on
bracket (9).
(4)