7-90. BATTERY BOX WIRING REPLACEMENT (145 AMP) (CONT).
(5)
Install cable 1138 (82) to starter (83) with
lockwasher (81) and nut (80).
(6)
Install cable 1139 (67) and cable 1055 (78) to
starter solenoid (79) with lockwasher (77)
and nut (76).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and water.
(7)
Apply electrical sealant to terminals (96)
(97) of starter (83) and starter solenoid (79)
(8)
Install negative terminals (75) on small post
at right rear of batteries (73) and tighten
nut (74) to 84 to 96 lb-in (9 to 11 N.m).
(9)
Install positive terminals (72) on large post
at left front of batteries (73) and tighten
nut (71) to 84 to 96 lb-in (9 to 11 N.m).
|