TM 9-2320-364-20-4
9-4
9-2. TRANSFER CASE SERVICE (CONT).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
(5)
Coat threads of pipe plug (4) with sealing compound.
(6)
Install pipe plug (4) in transfer case (3).
(7)
Coat threads of breather (1) with sealing compound.
(8)
Install breather (1) in street elbow (2).
c.
Follow-On Maintenance:
Start engine, (TM 9-2320-364-10).
Return LHS to transit position, (TM 9-2320-364-10).
Shut OFF engine, (TM 9-2320-364-10).
Check for oil leaks, (TM 9-2320-364-10).
Remove wheel chocks, (TM 9-2320-364-10).
END OF TASK
|