TM 9-2320-364-20-4
12-65
(6)
Remove tee (3) from relay spring valve (12).
(7)
Remove elbow (5) from relay spring
valve (12).
(8)
Remove elbow (7) from relay spring
valve (12).
(9)
Remove elbow (9) from relay spring
valve (12).
(10)
Remove three pipe plugs (14) from relay
spring valve (12).
b.
Installation.
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(1)
Apply sealing compound on threads of three
pipe plugs (14).
(2)
Install three pipe plugs (14) in relay spring
valve (12).
(3)
Apply sealing compound on threads of
elbow (9).
(4)
Install elbow (9) in relay spring valve (12).
(5)
Apply sealing compound on threads of
elbow (7).
(6)
Install elbow (7) in relay spring valve (12).
(7)
Apply sealing compound on threads of
elbow (5).
(8)
Install elbow (5) in relay spring valve (12).
(9)
Apply sealing compound on threads of tee (3).
(10)
Install tee (3) in relay spring valve (12).
|