TM 9-2320-364-20-5
17-73
(18)
Position wire 1281 (33) on relay R26 (34) with lockwasher (32) and nut (31). Tighten nut to 30 to 35 lb-in
(3 to 4 N.m).
(19)
Position wire 1430 (29) on relay R28 (30) with lockwasher (28) and nut (27). Tighten nut to 30 to 35 lb-in
(3 to 4 N.m).
(20)
Position wires 1075 (23), wire 1958 (24) and 1075B (25) on relay R25 (26) with lockwasher (23) and nut
(22). Tighten nut to 30 to 35 lb-in (3 to 4 N.m).
(21)
Push connectors MC9 (2), MC10 (3),
MC50 (9), MC51 (10), and MC36 (11)
through electronic control box (20).
(22)
Install two plates (18) to electronic control
box (20) with four screws (17) and two
rubber grommets (19).
(23)
Install wire harnesses (15) and (16) with
ferrites (14), screws (12) and locknuts (13).
|