TM 9-2320-364-20-5
18-36
18-8. CRANE HOOK BLOCK, HOOK AND CLEVIS REPAIR (CONT).
e.
Installation.
Wire rope can become frayed or
contain broken wires. Wear
heavy leather-palmed work
gloves when handling wire rope.
Never let moving wire rope slide
through hands, frayed or broken
wires can cause injury to
personnel.
(1)
Position cable (8) through hook block (9).
(2)
Position cable (8) through hole in open
wedge socket clevis (5).
(3)
Make loop in cable (8) and position free end
of cable through second hole in open wedge
socket clevis (5).
(4)
Install wedge (7) in cable loop. Drive wedge
and cable loop into open wedge socket
clevis (5).
NOTE
When installed properly, open
wedge socket clevis should rotate
freely on fly section.
(5)
Install open wedge socket clevis (5) on fly
section (6) with screw (4), washer (3), castle
nut (2) and cotter pin (1).
f.
Follow-On Maintenance:
Lubricate hook block, (Para 2-9).
Operate crane, (TM 9-2320-364-10).
Load test crane, (TM 9-2320-364-34).
Stow crane, (TM 9-2320-364-10).
Remove wheel chocks, (TM 9-2320-364-10).
END OF TASK
|