TM 9-2320-364-20-5 18-40      18-9.  AUXILIARY HAND PUMP REPAIR (CONT). (4) Install link (12) on pump (13) with pin (11) and two clips (10). (5) Install handle socket (9) in pump (13) with pin (8) and two clips (7). (6) Install pin (6) and two clips (5) in pump (13). (7) Coat preformed packings (3) and (4) with oil. (8) Install preformed packings (3) and (4) on elbows (1) and (2). (9) Install elbows (1) and (2) in pump (13). e. Installation. (1) Install pump (9) on mount (10) with four lockwashers (8) and screws (7).  Tighten screws to 17 lb-ft (23 N.m). (2) Install preformed packing (6) and hose (4) to elbow (5). (3) Install preformed packing (3) and hose (1) to elbow (2). f. Follow-On Maintenance: Check hydraulic fluid level, (Para 2-9, Lubrication Table 2-3). Operate pump and check for leaks, (TM 9-2320-364-10). Remove wheel chocks, (TM 9-2320-364-10). END OF TASK