TM 9-2320-364-20-5
20-29
a.
Removal.
Use extreme care when loosening filler cap. Sudden release of pressure could seriously injure
personnel. Slowly loosen cap to relieve pressure and ensure proper eye protection is worn.
(1)
Loosen filler cap (1) and relieve hydraulic pressure in hydraulic reservoir (2).
Ensure area on and around filter cover is clean prior to removal of filter cover to avoid
contamination of hydraulic fluid.
(2)
Loosen six screws (3) on filter cover (4).
NOTE
Filter cover is removed from filter base by turning to allow screw heads to pass through large
holes in filter cover.
(3)
Remove filter cover (4) from filter base (5).
(4)
Remove gasket (6) from filter cover (4). Discard gasket.
Remove hydraulic filter by holding the spring to avoid contamination of hydraulic fluid.
(5)
Remove hydraulic filter (7) from filter base (5).
|