TM 9-2320-364-20-5
21-24
21-7. ARCTIC KIT WATERJACKET REPLACEMENT (CONT).
(4)
Shut off ball valve (9).
(5)
Twist handle (10) and open front access cover (11).
(6)
Position drain pan under arctic waterjacket (12).
(7)
Remove plug (13) and gasket (14) from arctic waterjacket (12) and allow coolant to drain. Discard gasket.
|