TM 9-2320-364-20-5
21-29
(11)
Tighten clamp (15) on hose (16) to 40 lb-in
(5 N.m).
(12)
Tighten clamp (17) on exhaust tube (18).
(13)
Tighten clamp (19) on hose (20).
(14)
Install gasket (14) and plug (13) in arctic
waterjacket (12).
(15)
Close front access cover (11) and latch by
twisting handle (10).
(16)
Open ball valve (9).
|