TM 9-2320-364-20-5
21-32
21-8. ARCTIC KIT WIRE HARNESS REPLACEMENT (CONT).
NOTE
Connectors are removed by gently prying up on tab and pulling connectors apart.
Tag and mark all wires and connectors prior to removal.
Remove cable ties as required.
(2)
Disconnect MC120 connector (4).
(3)
Twist handle (5) and open front access cover (6).
(4)
Remove nut (7) and wire 1644 (8) from water pump (9).
(5)
Remove nut (10) and wire 1435 (11) from water pump (9).
b.
Installation.
NOTE
Install cable ties as required.
(1)
Install wire 1435 (11) and nut (10) on water pump (9).
(2)
Install wire 1644 (8) and nut (7) on water pump (9).
(3)
Close front access cover (6) and latch by twisting handle (5).
|