TM 9-2320-364-20-5
21-86
21-20. CONTAINER HANDLING UNIT (CHU) WIRE HARNESS REPLACEMENT (CONT).
b.
Installation.
NOTE
Install cable ties as required.
(1)
Position CHU wire harness (9) with MC189
connector (5) and two MC190 connectors (7)
along inside of frame (10) and in groove of
left hard lift deck bracket (11).
(2)
Position CHU wire harness (9) with MC188
connector (3) along inside of frame (12) with
existing wires.
(3)
Position CHU wire harness with MC185
connector (1) along inside of frame (13) with
existing wires.
(4)
Connect two MC190 connectors (7) to right
and left rear lock limit switch (8).
(5)
Connect MC189 connector (5) to mode
switch (6).
(6)
Connect MC188 connector (3) to hook up
arm proximity switch (4).
3
4
6
5
GROOVE
7
11
1
9
3
13
12
5
8
7
11
10
|