TM 9-2320-364-20-5
21-109
(2)
Remove three screws (3), washers (4) and cushion clips (5) from CHU wire harness (6) and arm
assembly (7).
(3)
Remove screw (8) and cushion clip (9) from CHU wire harness (6) and slider (10).
(4)
Remove two screws (11) and lock limit switch (12) from slider (10).
b.
Installation.
NOTE
Left and right lock limit switches are identical. Right lock limit switch is shown.
Install cable ties as required.
(1)
Position lock limit switch (12) with two screws (11) on slider (10). Do not tighten screws.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
(2)
Apply sealing compound to threads of screw (8).
(3)
Position cushion clip (9) on CHU wire harness (6) and install on slider (10) with screw (8).
4
12
10
9
8
7
5
11
3
6
6
|