TM 9-2320-364-20-5
21-112
21-26. CONTAINER HANDLING UNIT (CHU) REAR LOCK LIMIT SWITCH
REPLACEMENT/ADJUSTMENT (CONT).
(8)
Position container lock (6) in locked position
and install pin (5) and lock pin (4).
(9)
Remove two screws (8) from lock limit
switch (9).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in
well-ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and water.
(10) Apply sealing compound to threads of two
screws (8).
(11) Position lock limit switch (9) with two
screws (8) on slider.
NOTE
Lock limit switch is properly
adjusted when lever is depressed
and lock limit switch makes an
audible click.
(12) Position lock limit switch (9) against
container lock (6) until audible click is heard
and tighten two screws (8).
(13) Repeat Step (7) to check LHS for movement.
4
5
6
9
8
8
|