TM 9-2320-364-20-5
24-6
24-3. DECONTAMINATION KIT BRACKET REPLACEMENT (CONT).
b.
Installation.
(1)
Install two brackets (12) on bracket (3) with
four screws (11) and locknuts (10). Tighten
locknuts to 45 lb-ft (61 N.m).
(2)
Remove four plugs (9) from box
assembly (6).
(3)
Install two brackets (12) on box assembly (6)
and secure with two screws (8) and
locknuts (7).
(4)
Install two screws (5) and locknuts (4) in box
assembly (6).
(5)
Tighten locknuts (4) and (7) to 45 lb-ft
(61 N.m).
(6)
Install decontamination can (2) in
bracket (3) and secure with strap (1).
c.
Follow-On Maintenance:
Remove wheel chocks, (TM 9-2320-364-10).
END OF TASK
|