TM 9-2320-364-20-5
B-9
Section II. MAINTENANCE ALLOCATION CHART (CONT).
(1)
(6)
(5)
(4)
(3)
(2)
Maintenance Level
General
Direct
Group
Tools and
Depot
Support
Support
Unit
Maintenance
Number
Remarks
Equipment
D
H
F
O
C
Function
Component/Assembly
0602
Generator Alternator
(Voltage):
Voltage Regulator
Adjust
Test
Replace
0.3
0.5
0.1
1, 4
4
1
A
Polarity Protection
Control (145 AMP)
Adjust
Test
Replace
0.3
0.5
1.5
1, 4
4
1
A
Polarity Protection
Control (200 AMP)
Test
Replace
0.5
1.5
4
1
A
0603
Starting Motor:
Starter Motor
Test
Replace
Repair
0.3
2.6
4.0
4
1, 2, 4
6, 8, 10
0607
Instrument or Engine
Control Panel:
Instrument Panel
Gages Wire Harness
Replace
Repair
2.5
*
1
C,E
Instrument Panel
Switch Wire Harness
Replace
Repair
1.0
*
1
C,E
0608
Miscellaneous Items:
Ether Start Aid
Switch
Service
Replace
0.4
1.2
1
Crane Junction Box
Replace
Repair
2.0
1.0
5, 6
5, 6
Proximity Switches
(LHS) (each)
Replace
Adjust
Test
0.5
*
0.5
1, 2, 71
1, 4
C
Proximity Switch
(Outrigger)
Replace
Adjust
Test
0.5
*
0.5
1
1, 2
C
|