TM 9-2320-364-34-2
3-154
3-26. ENGINE OIL PUMP REPAIR (CONT).
c.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all parts with drycleaning solvent and allow to air dry.
(2)
Inspect oil pump for cracks or other damage.
(3)
Inspect drive gear for worn or broken gear teeth.
(4)
Replace all damaged parts.
d.
Assembly.
(1)
Install gasket (23) and strainer adapter (22)
on oil pump (16) with two lockwashers (21)
and screws (20).
(2)
Install strainer (19) on strainer adapter (22)
with two washers (18) and self-locking
screws (17).
|