TM 9-2320-364-34-2
4-49
b.
Installation.
Ensure all debris is kept clear of
blower during installation.
Failure to comply may result in
damage to equipment.
(1)
Remove wiping rag from blower (16).
(2)
Apply grease to gasket (17).
(3)
Position gasket (17) on fuel pump (14).
(4)
Align drive coupling fork (15) in fuel
pump (14) with blower shaft and position
fuel pump (14) on blower housing (16).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(5)
Coat threads of three screws (13) with
sealing compound.
(6)
Install screws (13) in fuel pump (14).
Tighten 120 to 156 lb-in (14 to 18 N.m)
(7)
Remove wiping rags from engine (12).
(8)
Install fuel hose 3572 (10) to tee (11).
(9)
Install fuel hose 2260 (8) on elbow (9).
(10)
Connect connector (6) on sensor (7).
|