TM 9-2320-364-34-2
6-16
6-2. ALTERNATOR ASSEMBLY REPAIR (145 AMP) (CONT).
Cover can only be installed
one way. Pins in cover must
be positioned over brush
holes.
1/16 in. socket head screw
key must be removed before
screws are fully tightened, or
damage to equipment may
result
(25)
Install gasket (11) and cover (9) with four
screws (10) in brush housing (13).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
(26)
Clean the bottom surface of capacitor (8) and cover (9) with an equal mixture of isopropyl alcohol and
water, and let air dry.
(27)
Install two sided tape (62) to the bottom surface of capacitor (8).
(28)
Install capacitor (8) on cover (9) with two lockwashers (7) and nuts (6).
(29)
Press capacitor (8) firmly to cover (9) with two lockwashers (7) and nuts (6).
(30)
Apply corrosion preventive compound to
two terminals on cover (9).
(31)
Install spacer (4), key (3) and fan (2) on
shaft (5) with nut (1).
END OF TASK
|