TM 9-2320-364-34-2
6-66
6-9. HOIST PROXIMITY SENSOR REPLACEMENT/ADJUSTMENT (CONT).
(2)
Disconnect overload harness connector
from overload box (6).
NOTE
Hoist proximity sensor cable is
positioned in bottom of overload
box.
(3)
Remove two screws (7), lockwashers (8),
washers (9), hoist proximity sensor (10) and
bracket (11) from cable guide bracket (12).
Discard lockwashers.
(4)
Remove nut (13) and hoist proximity sensor
(10) from bracket (11).
b.
Installation.
NOTE
Install cable ties as required.
(1)
Position hoist proximity sensor (10) on
bracket (11) with two nuts (13) until outer
edge of hoist proximity sensor (10) is 1 in.
(25.4 mm) from edge of bracket (11),
Measurement A.
NOTE
Position hoist proximity sensor
cable in bottom of overload box.
(2)
Install hoist proximity sensor (10) and
bracket (11) on cable guide bracket (12)
with two washers (9), lockwashers (8) and
screws (7).
|