TM 9-2320-364-34-2
6-192
6-22. STE/ICE-R ALTERNATOR HARNESS REPLACEMENT (200 AMP)(CONT).
(5)
Remove nut (10) and washer (12) from 12
volt terminal (15)
(6)
Install wire 1860 (13), washer (12),
lockwasher (11) and nut (10) on 12 volt
terminal.
(7)
Tighten nut (10) to 15 lb-ft (20 Nm).
(8)
Remove nut (2), washer (4), washer(s) (5)
(if present), and fuse link (6) with insulator
washer (7) from 24 volt terminal (9).
(9)
Install wire 1820/1953 (8), fuse link (6) with
insulator washer, washer(s) (5) (if removed),
washer (4), lockwasher (3) and nut on 24
volt terminal.
(10)
Tighten nut (2) to 15 lb-ft (20 Nm).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(11)
Apply electrical sealant to 24 volt terminal
(9), 12 volt terminal (14) and screw (15).
(12)
Connect MC24 connector (1).
c.
Follow-On Maintenance:
Install left front noise panel,
(TM 9-2320-364-20).
Install cab engine access panel,
(TM 9-2320-364-20).
Connect batteries, (TM 9-2320-364-20).
Remove wheel chocks, (TM 9-2320-364-10).
1
13
12
11
10
4
8
3
7
6
2
5
5
14
9
|