TM 9-2320-364-34-2
6-208
6-24. ELECTRONIC CONTROL BOX LIGHT WIRE HARNESS REPLACEMENT (CONT).
b.
Installation.
NOTE
Install cable ties as required.
Refer to Table 6-3 for wire
locations.
(1)
Position light wire harness (35) in ECB (36).
(2)
Install relay sockets R1 (27) and R6 (32)
with two lockwashers (34) and screws (33).
(3)
Install six 12V relays (26) in relay
sockets R1 (27), R2 (28), R3 (29), R4 (30),
R5 (31) and R6 (32).
(4)
Connect MC52 connector (25).
|