TM 9-2320-364-34-2
6-212
6-25. ELECTRONIC CONTROL BOX WIRE HARNESS REPLACEMENT (CONT).
(3)
Remove five 12V relays (7) from relay
sockets R7 (8), R8 (9), R9 (10), R10 (11)
and R11 (12).
(4)
Remove screw (13) and lockwasher (14)
from relay socket R11 (12). Discard
lockwasher.
(5)
Remove five 12V relays (7) from relay
sockets R13 (15), R14 (16), R15 (17),
R16 (18) and R17 (19).
(6)
Remove eight 24V relays (20) from relay
sockets R12 (21), R18 (22), R19 (23), R20
(24), R21 (25), R22 (26), R23 (27) and
R24 (28).
(7)
Remove three screws (13), lockwashers (14)
from relay sockets R12 (21), R17 (19)
and R24 (28). Discard lockwashers.
15
7
16
17
18
19
|