TM 9-2320-364-34-2
6-293
(2)
Installation.
NOTE
All harnesses and caps are
installed in junction box the
same way.
(a)
Position cap (9), washer (10) and
grommet (11) on end of harness (12).
(b)
Position harness (12) in junction
box (4) and install grommet (11),
washer (10) and cap (9).
NOTE
Connect only wires required
to complete task. Refer to
Table 6-5 and Figure 6-3 for
specific junction box wire
replacement.
Install cable ties as required.
(c)
Connect harness wires (5) to terminal
strip (6), ground strip (7) and
diodes (8) in junction box (4).
(d)
Position cover (3) on junction box (4).
(e)
Position six clips (2) over cover (3) and
tighten six screws (1).
|