6-36. REVERSE POLARITY WIRING HARNESS REPLACEMENT (145 AMP) (CONT).
(24)
Connect voltage regulator harness (44) to
voltage regulator (45).
(25)
Install wire 1021A (42), lockwasher (41)
and nut (40) on stud (43) of 24 volt
solenoid switch (36).
(26)
Install capacitor wire (38), wire 1045 (37),
lockwasher (33) and nut (32) on stud (39)
of 24 volt solenoid switch (36).
(27)
Install wire 1281 (34), lockwasher (33) and
nut (32) on stud (35) of 24 volt solenoid
switch (36).
|