TM 9-2320-364-34-2
6-425
(36)
Connect ATEC electrical connector (26) on transmission (27).
Upon installation of all wires and cables, ensure no contact is made with battery terminals
or other wires and cables. Strap wires and cables away from battery terminals and other
wires and cables as required to prevent damage to parts, personal injury, or death.
Battery acid (electrolyte) is extremely harmful. Always wear safety goggles and rubber
gloves, and do not smoke when performing maintenance on batteries. Injury will result if
acid contacts skin or eyes. Wear rubber apron to prevent clothing being damaged.
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact
positive electrical circuits, a direct short may result. Damage to equipment, injury or death
to personnel may occur.
Do not over-torque terminal
connectors, damage to terminals
can result.
NOTE
If arctic batteries are installed,
perform Steps (37) through (42).
If not, go to Step (43).
(37)
Install two terminals (24) on positive
battery posts (25) and tighten two nuts (23)
to 84 to 96 lb-in (9 to 11 N.m) on arctic
batteries (22).
(38)
Install two terminals (20) on negative
battery posts (21) and tighten two nuts (19)
to 84 to 96 lb-in (9 to 11 N.m) on arctic
batteries (22).
|