TM 9-2320-364-34-2
3-45
(71)
Install wire 1819 (43) and two
cables 1138 (42) on negative terminal (44)
on starter (45) with lockwasher (41) and
nut (40).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(72)
Coat negative terminal (44) with electrical
sealant.
NOTE
If equipped with a 145 AMP
alternator, perform Steps
(73) through (78).
If equipped with 200 AMP
alternator, perform Steps
(79) through (87).
(73)
Install wires 1953 (38) and 1344 (37) to
F-positive post (39) on top of alternator (29)
with lockwasher (36) and nut (35).
(74)
Coat F-positive post (39) with electrical
sealant.
(75)
Install wires 1278 (33) and 1820 (32) to
positive post (34) on alternator (29) with
lockwasher (31) and nut (30).
(76)
Coat positive post (34) with electrical
sealant.
(77)
Install wires 1275 (27), 1057 (26), 1435 (25)
and 1815 (24) to negative post (28) on
alternator (29) with lockwasher (23) and
nut (22).
(78)
Coat negative post (28) with electrical
sealant.
|