TM 9-2320-364-34-2
10-17
(8)
Remove air supply and adapter from lower
supply port (8).
(9)
Remove air pressure gage from lower
delivery port (7) on backside of treadle
valve (1).
(10)
Remove two pipe plugs (4) from upper
ports (5) and (6) on backside of treadle
valve (1).
(11)
Install two pipe plugs (4) in lower ports (7)
and (8) on backside of treadle valve (1).
(12)
Install air pressure gage in upper delivery
port (6) on backside of treadle valve (1).
Air pressure should be between
80 to 120 psi (552 to 827 kPa).
Failure to comply may result in
damage to equipment.
(13)
Install air supply line and adapter in upper
supply port (5).
7
8
1
5
6
4
ADAPTER
AIR
SUPPLY
LINE
AIR PRESSURE
GAGE
ADAPTER
AIR
SUPPLY
LINE
AIR PRESSURE
GAGE
1
5
6
4
8
7
|