TM 9-2320-364-34-3
14-62
14-9. LONGITUDINAL TORQUE ROD REPLACEMENT (CONT).
(c)
With the aid of an assistant, install
torque rod (12) and air manifold
bracket (4) on axle (5) with two
screws (3), four washers (2) and two
locknuts (1).
NOTE
Frame must be level to perform axle camber adjustment properly.
Axle camber angle measurements must be taken with relationship to frame. If frame is not
level, the angle the frame is inclined must be added or subtracted from the flange assembly
measurement.
Axle flange measurement of 85 0.5 degrees equals axle camber of five degrees 0.5 (90
degrees 85 degrees = 5 degrees).
(d)
Measure the angle (in degrees) that
flange assembly is cambered.
1
Position protractor and steel plate
on frame at point A. Adjust
protractor to zero.
2
Position protractor and steel plate
on machined surface of the flange
assembly and record measurement.
This is point B. Measurement
should read 85 degrees 0.5
degrees.
(e)
If axle camber is not three degrees
0.5 degrees, add or subtract spacers (14)
until correct axle camber is achieved.
|