TM 9-2320-364-34-3
16-162
16-25. TENSION LOAD CELL REPLACEMENT (CONT).
a.
Removal.
Hoist weighs 210 lbs (95 kg). Attach suitable lifting device prior to removal to prevent
possible injury to personnel.
(1)
Attach lifting device around hoist assembly (1).
(2)
Remove screw (2) and block (3) from end cap (4).
To avoid damage to tension load cell, hold cable while removing nuts. Do not allow
tension load cell to move or wiring may be damaged.
To avoid damage to load cell, use care when lowering or raising hoist assembly.
NOTE
Count exposed threads on tension load cell before nuts are removed to ensure nuts are
reinstalled to the same positions.
Raise or lower lifting device to allow hoist assembly to rotate forward and down slightly to
gain better access to nuts during removal.
(3)
Remove jam nut (5), swivel nut (6), swivel nut (7) and end cap (4) from tension load cell (8).
|