Four valve bank weighs 75 lbs
(34 kg). Attach suitable lifting
device prior to removal to
prevent possible injury to
personnel.
(9)
Attach lifting device to four function control
valve bank (27).
(10)
Loosen four screws (32) in left and right
brackets (17) and (18).
(11)
Remove four screws (33), lockwashers (34)
and move four function control valve bank
(27) away from brackets (17) and (18).
(12)
Remove hose (35) and preformed
packing (36) from four function control
valve bank (27). Discard
preformed packings.
(13)
Position four function control valve
bank (27) on blocking and remove lifting
device.
|