TM 9-2320-364-34-3
16-188
16-26. FOUR FUNCTION CONTROL VALVE BANK REPAIR (CONT).
e.
Installation.
Four valve control valve bank
weighs 75 lbs (34 kg). Attach
suitable lifting device prior to
installation to prevent possible
injury to personnel.
(1)
Attach lifting device to four valve control
valve bank (27).
(2)
Position four function control valve
bank (27) loosely between left and right
mounting brackets (17) and (18).
(3)
Apply hydraulic oil to preformed
packing (36).
(4)
Install preformed packing (36) and hose
(35) on four function control valve
bank (27).
|