TM 9-2320-364-34-3
16-193
a.
Removal.
The crane hydraulic system
operates at oil pressures up to
3,100 psi (21,375 kPa). Never
disconnect any hydraulic line or
fitting without first dropping the
pressure to zero. Failure to
comply may result in serious
injury or death to personnel.
NOTE
Tag and mark hydraulic
hoses prior to removal.
Cap and plug hydraulic
hoses and tubes after
removal.
(1)
Position drain pan under crane (1).
(2)
Disconnect hose (2) from elbow (3) on three
function control valve bank (4) and remove
preformed packing (5). Discard preformed
packing.
(3)
Disconnect hose (6) from tube (7) and
remove preformed packing (8). Discard
preformed packing.
(4)
Disconnect tube (7) from fitting (9) and
elbow (10) and remove two preformed
packings (11). Discard preformed packings.
|