TM 9-2320-364-34-3      16-193 a. Removal. The crane hydraulic system operates at oil pressures up to 3,100 psi (21,375 kPa).  Never disconnect any hydraulic line or fitting without first dropping the pressure to zero.  Failure to comply may result in serious injury or death to personnel. NOTE Tag and mark hydraulic hoses prior to removal. Cap and plug hydraulic hoses and tubes after removal. (1) Position drain pan under crane (1). (2) Disconnect hose (2) from elbow (3) on three function control valve bank (4) and remove preformed packing (5).  Discard preformed packing. (3) Disconnect hose (6) from tube (7) and remove preformed packing (8).  Discard preformed packing. (4) Disconnect tube (7) from fitting (9) and elbow (10) and remove two preformed packings (11).  Discard preformed packings.