TM 9-2320-364-34-3
16-208
16-29. FOUR/THREE VALVE BANK MOUNT REPLACEMENT (CONT).
(5)
Remove cap (8) from connector (9).
(6)
Remove cap (8) from bracket (4).
(7)
Remove nut (10), lockwasher (11) and
connector (9). Discard lockwasher.
(8)
Drill out four rivets (12) and remove data
plate (13) from bracket (4).
(9)
Remove two nuts (14), lockwashers (15),
washers (16), mount (17), washers (18) and
screws (19) from subframe (20). Discard
lockwashers.
(10)
Remove two screws (21), lockwashers (22),
washers (23) and mount (4). Discard
lockwashers.
b.
Installation.
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(1)
Apply sealing compound on threads of two
screws (21).
(2)
Install mount (4) on subframe (20) with two
screws (21), lockwashers (22) and
washers (23). Tighten screws to 17 lb-ft
(23 N.m).
(3)
Apply sealing compound on threads of two
screws (19).
(4)
Position mount (17) and install with two
screws (19), washers (18), washers (16),
lockwashers (15) and nuts (14). Tighten
nuts to 17 lb-ft (23 N.m).
|