TM 9-2320-364-34-3
16-228
16-34. HOIST, BOOM, TELESCOPE, SWING SOLENOID VALVE REPAIR (CONT).
b.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all metal parts in drycleaning solvent.
(2)
Inspect each part for nicks, scratches and burrs.
(3)
Replace damaged parts.
c.
Assembly.
NOTE
All four solenoids are assembled
the same way.
(1)
Install armature (18) in case (10).
(2)
Install sleeve (17) in case (10).
(3)
Install tube (16) in coil (9).
(4)
Apply hydraulic oil to quad ring (15).
(5)
Install quad ring (15) on push pin (14).
(6)
Install push pin (14) in plug (11).
(7)
Apply hydraulic oil to preformed
packing (22).
(8)
Position preformed packing (12) on
plug (11) and install plug (11) in armature
assembly (7).
(9)
Position coil (9) in case (10).
(10)
Position push pin (8) and armature
assembly (7) in coil (10).
|