TM 9-2320-364-34-3
17-101
a.
Removal.
The LHS hydraulic system operates at oil pressures up to 3,625 psi (24,994 kPa). Never
disconnect any hydraulic line or fitting without first dropping pressure to zero. Failure to
comply may result in serious injury or death to personnel.
NOTE
Tag and mark wires and hoses prior to removal.
Remove cable ties as required.
Cap and plug all hoses after removal.
(1)
Position drain pan under multifunction manifold (1).
(2)
Disconnect hose 2777 (2) at quick disconnect (3).
|