TM 9-2320-364-34-3
18-27
(15)
Install polarity protection control (18) with
washers (19), lockwashers (20) and screws
(21) on electric bracket (22).
NOTE
Polarity protection control is
properly installed when 12V BAT
and 12V LOAD terminals are on
top.
(16)
Position 200 AMP polarity wire harness
(23) in truck.
(17)
Install capacitor (24) on studs (25) and
(26).
(18)
Install jumper diode (27) with negative
terminal on stud (28) and positive terminal
on stud (25).
(19)
Install wire 1435 (29), wire 1435 (30) of
200 AMP polarity wire harness (23),
lockwasher (31) and nut (32) on stud (25)
of 24 volt solenoid switch (33).
(20)
Install wire 1021A (34) of 200 AMP
polarity wire harness (23), lockwasher (35)
and nut (36) on stud (28) of 24 volt
solenoid switch (33).
22
18
21
20
19
24
32
27
36
33
31
35
28
34
30
29
25
26
|