TM 9-2320-364-34-3
18-181
CARC paint contains isocyanate (HDI) which is highly irritating to skin and respiratory
system. High concentrations of HDI can produce symptoms of itching and reddening of skin, a
burning sensation in throat and nose and watering of the eyes. In extreme concentrations, HDI
can cause cough, shortness of breath, pain during respiration, increased sputum production,
and chest tightness. The following precautions must be taken whenever using CARC paint:
ALWAYS use air line respirators when using CARC paint unless air sampling shows
exposure to be below standards. Use chemical cartridge respirator if air sampling is below
standards.
DO NOT let skin or eyes come in contact with CARC paint. Always wear protective
equipment (gloves, ventilation mask, safety goggles, etc.).
DO NOT use CARC paint without adequate ventilation.
NEVER weld or cut CARC-coated materials.
DO NOT grind or sand painted equipment without high-efficiency air purifying respirators
in use.
BE AWARE of CARC paint exposure symptoms; symptoms can occur a few days after
initial exposure. Seek medical help immediately if symptoms are detected.
NOTE
Reuse parts from removal and disassembly of rear marker light assembly.
Inspect all wires, connectors, parts for cracks and damage and replace as necessary.
There are two blackout lights. Both blackout lights are installed the same way.
Light bar can be found in CHU crate secured with wood blocking securing rear brackets.
Rear brackets can be found in box A, pack no. 4 of CHU kit crate.
(201)
Grind off paint on areas of marker light bar
assembly (230) and rear brackets (231) for
grounding surfaces.
230
231
231
|