TM 9-2320-364-34-4
20-286
20-85. WATER PUMP ASSEMBLY INSTALLATION. (CONT).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(12)
Apply sealing compound to threads of four
screws (3).
(13)
Position hose (2) and two clamps (1) on
adapter (4).
(14)
Install gasket (5) and water pump discharge
to adapter (4) on oil cooler housing (6) with
four screws (2).
(15)
Tighten screws (2) 30 to 35 lb-ft (41 to 47
N.m).
(16)
Tighten two clamps (1) on hose (2).
b.
Follow-On Maintenance:
Install aftercooler, (Para 20-86).
END OF TASK
|