TM 9-2320-364-34-4
20-330
20-103. TURBOCHARGER AND AIR INLET HOUSING INSTALLATION (CONT).
(20)
Position ether start tube (7) on engine (10).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(21)
Coat threads of atomizer (8) with sealing
compound.
(22)
Install atomizer (8) in air inlet housing (9).
(23)
Install ferrule (6), ether tube (7) and nut (5)
on atomizer (8).
Gloves must be used when
handling turbocharger cover.
Turbocharger cover is made of
fiberglass and may cause skin
irritation. Failure to comply
may result in injury to personnel.
(24)
Install cover (3) on turbocharger
assembly (4) and secure with two wires (1)
through tabs (2).
b.
Follow-On Maintenance:
Install ECM, (Para 20-104).
END OF TASK
|