TM 9-2320-364-34-4
23-48
23-11. TORQUE CONVERTER PUMP REPAIR (CONT).
Ensure tangs of hub engage
properly in torque converter
pump or damage to equipment
could result.
(5)
Install torque converter pump (8) in torque
converter housing (1).
NOTE
Torque converter pump is seated
when retaining ring groove is
visible.
(6)
Position sleeve on ground sleeve (3).
(7)
Drive torque converter pump (8) down until
seated.
(8)
Remove sleeve from ground sleeve (3).
NOTE
Spacer must be installed flat side
down over ground sleeve.
(9)
Install spacer (4) over ground sleeve (3).
Use care when installing
retaining rings. Retaining rings
are under tension and can act as
projectiles when released causing
injury to personnel.
(10)
Using snap ring remover, install retaining
ring (2) on ground sleeve (3).
f.
Follow-On Maintenance:
Install torque converter stator assembly, (Para 23-10).
END OF TASK
|